{"product_id":"hlc-1xv02aac1p-30a-277vac-definite-purpose-contactor","title":"HLC-1XV02AAC(1P\/30A\/277VAC) DEFINITE PURPOSE CONTACTOR","description":"\u003ctable width=\"564\" cellspacing=\"0\" cellpadding=\"2\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003e\u003cspan\u003e*Applicable and Description\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ctable width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" border=\"0\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e1. Applicable Scope\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHLC-1XV02AAC(1P\/30A\/277VAC) Definite Purpose Contactor\u003c\/span\u003e(Follow Defers To DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 240V Or 277V The Nominal Current Up To The 30A Electric Circuit, Is Suitable For The Starting And The Control Single-Phase Motor (Or Compressor) And Other Single-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e2.Type and Meaning\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" border=\"0\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1X\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eV\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompany Code\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003ctd\u003ePacking Y : Individual Box Pack    - : Factory Bulk Pack\u003c\/td\u003e\n\u003ctd\u003ePole: One Pole with Shunt\u003c\/td\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003eRating of current\u003c\/td\u003e\n\u003ctd\u003eTerminal\u003c\/td\u003e\n\u003ctd\u003eWith Cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003e\u003cspan\u003e*Product Explanation And Main Technical Parameter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ctable width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" border=\"0\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eHLC-1XU02AAC(1P\/30A\/208-240VAC) Definite Purpose Contactor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC60947\u003c\/td\u003e\n\u003ctd\u003eUL508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating of Current\u003c\/td\u003e\n\u003ctd\u003eIe 30A\u003c\/td\u003e\n\u003ctd\u003eFLA: 30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistive Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIth 40A\u003c\/td\u003e\n\u003ctd\u003eRES: 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating of Contacts Voltage\u003c\/td\u003e\n\u003ctd\u003eUe 240\/277V\u003c\/td\u003e\n\u003ctd\u003e240\/277\/480\/600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating of Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUi 660V\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating of Coil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUs 277V\u003c\/td\u003e\n\u003ctd\u003eUs: 277VAC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000,000 Cycle\u003c\/td\u003e\n\u003ctd\u003e1000,000 Cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectricity life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,000 Cycle\u003c\/td\u003e\n\u003ctd\u003e250,000 Cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eProduct Explanation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cstrong\u003e1.Product Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHLC-1XV02AAC\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIs Suitable To Exchanges 50 Or 60hz, Fixed Working Voltage To 240v or 277v, Fixed Operating Current To 30A Single-Phase Load Circuit Control,At Present, Widely Applies To The Single-Phase Mechanical Device Main Circuit As Well As The Single-Phase Air-Conditioner Compressor Control.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003e2 .The Regular Service Conditon And Installs The Condition\u003c\/strong\u003e \u003cbr\u003ea. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets\u003cbr\u003eDown The Limiting Value Is -25 \u003cbr\u003eb. The Installation Site Elevation Does Not Surpass 2000m \u003cbr\u003ec. The Air Pollution Rank Is 2 Levels \u003cbr\u003ed. Installs The Category Is Ii ; \u003cbr\u003ee. Installment Facing The Gradient Does Not Surpass ±5° \u003cbr\u003ef. Not Remarkable Undulation, Impact And Vibration Place.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3 .Main Technical Parameter\u003c\/strong\u003e \u003cbr\u003ea. Contactor Coil Picking Up In 75% ~ 110% Us Reliably \u003cbr\u003eWorking, Its Drop Out Voltage In 20% ~ 70%Us \u003cbr\u003eb. Contactor Use Category: Ac-1Ac8a \u003cbr\u003ec. Contactor In With 0.4m Place, Its Noise Below 40db.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4 . Installing Specification And Install Size\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ea. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than ±5°\u003c\/p\u003e\n\u003cp\u003eb. Before The Use Should Inspect The Power Terminal And The Contactor \u003cbr\u003eQuick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating \u003cbr\u003eThe Breakdown, Behind Check Off May Electrify Tries . \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e\u003cstrong\u003e*Conforms To The Standard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ctable width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" border=\"0\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\n\u003cp\u003e\u003cstrong\u003eConforms To National Standard And International Standard\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1 Conforms To \u003cstrong\u003eUL508, IEC60947, GB14048\u003c\/strong\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 Approved By \u003cstrong\u003eUL,CUL,TUV,CE,CCC\u003c\/strong\u003e,Safe Certification and \u003cstrong\u003eISO9001\u003c\/strong\u003e System Certification(SGS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCCC Certificate Number:\u003c\/strong\u003e  2005010309156761\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUL Files Number:\u003c\/strong\u003e E251539\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003e\u003cspan\u003e*Ordering Request\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cstrong\u003eIn Order To Guarantee You Purchase Right, Please Read The Specify Type Before Order.\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eContactor Specification Model, Pole Number, Coil Control Voltage, Rating Of Operating Current, Wiring Way(Terminal), Whether With Cover ,The Packing Way, Etc\u003c\/p\u003e\n\u003ctable width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" border=\"0\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIf You Request As Follows: Nominal Current: 30A, Working Voltage: 240\/277V,480V,600V, Pole Number: One Pole Without Shunt, Coil Control Voltage:208-240V, Wiring Way: Quick Connect, Load Current: Single-Phase Motor Controls Or Heating Load, Packing: 50\/Each Box (Factory Packing), With The Cover. Then You May Be Elect The Type : \u003cstrong\u003eHLC-1XV02AAC\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eLifts The Samples As Follows (Contains Derivation Type From This Model)\u003c\/strong\u003e \u003c\/p\u003e\n\u003ctable width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" border=\"0\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRating of Current\n\u003cp\u003e\u003cstrong\u003eIe\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003ePole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cstrong\u003eRating of Coil Control Voltage\u003c\/strong\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Motor Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24VAC\u003c\/td\u003e\n\u003ctd\u003e120VAC\u003c\/td\u003e\n\u003ctd\u003e208\/240VAC\u003c\/td\u003e\n\u003ctd\u003e277VAC\u003c\/td\u003e\n\u003ctd\u003e380\/480VAC\u003c\/td\u003e\n\u003ctd\u003e240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1P\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHLC-1XQ02AAC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eHLC-1XT02AA\u003c\/span\u003e\u003cspan\u003eC\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eHLC-1XU02AA\u003c\/span\u003e\u003cspan\u003eC\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eHLC-1XV02AAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHLC-1XH02AAC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5Kw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hongli Electric","offers":[{"title":"Default Title","offer_id":14384321298491,"sku":"HLC-1XV02AAC","price":22.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0091\/0458\/8859\/products\/HLC-1XV02AAC-001.jpg?v=1536285440","url":"https:\/\/www.goodspec.com\/vi-sd\/products\/hlc-1xv02aac1p-30a-277vac-definite-purpose-contactor","provider":"HONGLI ELECTRIC CO.,LTD","version":"1.0","type":"link"}